[1]刘刚,钱建庭,李先明,等.X射线光声成像的信号检测与仿真[J].深圳大学学报理工版,2018,35(3):324-330.[doi:10.3724/SP.J.1249.2018.03324]
 LIU Gang,CHIN C T,LI Xianming,et al.Simulation and experimental detection of X-ray photo-acoustic[J].Journal of Shenzhen University Science and Engineering,2018,35(3):324-330.[doi:10.3724/SP.J.1249.2018.03324]
点击复制

X射线光声成像的信号检测与仿真()
分享到:

《深圳大学学报理工版》[ISSN:1000-2618/CN:44-1401/N]

卷:
第35卷
期数:
2018年第3期
页码:
324-330
栏目:
电子与信息科学
出版日期:
2018-05-15

文章信息/Info

Title:
Simulation and experimental detection of X-ray photo-acoustic
文章编号:
201803012
作者:
刘刚1钱建庭1李先明2郑溪园2李炜澔2林运政3谢兵3刁现芬1
1)深圳大学医学部生物医学工程学院,广东深圳 518071
2)深圳市人民医院肿瘤放射科,广东深圳 518020
3)深圳市宝安人民医院肿瘤放射科,广东深圳 518060
Author(s):
LIU Gang1 CHIN C T1 LI Xianming2 ZHENG Xiyuan2 LI Weihao2 LIN Yunzheng3 XIE Bing3 and DIAO Xianfen1
1) School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen 518071, Guangdong Province, P.R.China
2) Department of Radiation Oncology, Shenzhen People’s Hospital, Shenzhen 518020, Guangdong Province, P.R.China
3) Department of Radiation Oncology, Shenzhen Baoan People’s Hospital, Shenzhen 518060, Guangdong Province, P.R.China
关键词:
生物医学工程医学成像技术X射线脉冲光声信号检测K-wave仿真光电检测电路
Keywords:
biomedical engineering medical imaging technology X-ray pulse photo-acoustic (PA) signal detection K-wave simulation photodiode detection circuit
分类号:
O 426.9; R 318
DOI:
10.3724/SP.J.1249.2018.03324
文献标志码:
A
摘要:
通过理论仿真和实验检测结果,分析由医用直线加速器产生的X射线照射铅块所产生的光声信号特性.使用光电二极管搭建一个光电检测电路,检测到医用直线加速器所产生的脉冲X射线的光脉冲宽度约为4 μs.采用K-wave工具包仿真分析脉冲宽度为几个微秒的光脉冲所产生的光声信号.搭建了一个光声信号检测系统,对比分析分别使用Olypus V301商用探头与自制的PZT-4陶瓷换能器时的检测性能.结果表明,两款探头都检测到了光声信号,V301商用探头检测结果与理论仿真波形一致性较好,但信噪比低,而本研究设计的PZT-4检测灵敏度高,但检测到的信号波形与理论仿真结果偏差较大.两款探头在检测脉冲宽度为4 μs 的X射线脉冲所产生的声信号时都存在不足,为更好的检测该光声信号,需设计一款中心频率在70 kHz附近、带宽较宽、检测灵敏度较高的探头.
Abstract:
The aim of this paper is to analyze the characteristics of the photo-acoustic (PA) signal, which is induced by irradiating the lead with X-ray from a medical linear accelerator. Related theoretical simulations and experiments are done. A photodiode detection circuit is put up to detect the width of X-ray pulses, which is about 4 μs. The K-wave software is used to simulate and analyze the PA signal generated by X-ray whose pulse width was several microseconds. We also put up a single element photo-acoustic signal acquisition system and carry out the comparative experiments with Olympus V301 commercial probe and the probe designed by the piezoelectric ceramics PZT-4. Results show that both probes can detect the PA signal. The signal detected by V301 is in good accordance with the simulation signal waveform, but has low signal noise ratio. The probe designed by PZT-4 has high sensitivity, but the detected signal deviates from the simulation waveform. Both probes have shortcomings in detecting the PA signals generated by X-ray pulse with a pulse width of 4 μs. Both simulation and experiment results indicate that a probe with high sensitivity, wide bandwidth and 70 kHz center frequency should be designed to detect the PA signal without distortion and with higher signal noise ratio.

参考文献/References:

[1] 钱梦騄, 魏墨盦.光声效应及光声检测系统[J].声学技术, 1985(2):1-6.
QIAN Menglu, WEI Moan. Photoacoustic effect and photoacoustic detection system[J]. Tcehnical Acoustics. 1985(2): 1-6.(in Chinese)
[2] YAO Junjie, WANG Lidai, YANG J M, et al. High-speed label-free functional photoacoustic microscopy of mouse brain in action[J]. Nature Methods, 2015, 12(5): 407-410.
[3] WANG L V, YAO Junjie. A practical guide to photoacoustic tomography in the life sciences[J]. Nature Methods, 2016, 13(8): 627-638.
[4] ALLES E J, JAEGER M, BAMBER J C. Photoacoustic clutter reduction using short-lag spatial coherence weighted imaging[C]// IEEE International Ultrasonics Symposium. Chicago, USA: IEEE, 2014:41-44.
[5] ZHAO Yue, YANG Sihua, CHEN Conggui, et al. Simultaneous optical absorption and viscoelasticity imaging based on photoacoustic lock-in measurement[J]. Optics Letters, 2014, 39(9): 2565-2568.
[6] SONG LIANG, DIBELLA E V, CHEN Rongrong, et al. K-t ISD: dynamic cardiac MR imaging using compressed sensing with iterative support detection[J]. Magnetic Resonance in Medicine, 2012, 68(1): 41-53.
[7] MASUJIMA T. Photoacoustic x-ray absorption-spectroscopy[M]// Topics in Current Chemistry: Synchrotron Radiation in Chemistry and Biology II. 1988, 147: 145-157.
[8] BOWEN T, CHEN C X, LIEW S C,et al. Observation of ultrasonic emission from edges of therapeutic x-ray beams[J]. Physics in Medicine Biology, 1991, 36(4): 537-539.

[9] XIANG L, HAN B, CARPENTER C, et al. X-ray acoustic computed tomography with pulsed x-ray beam from a medical linear accelerator[J]. Medical Physics, 2013, 40(1): 010701.
[10] XIANG Liangzhong, TANG Shanshan, AHMAD M, et al. High resolution X-ray-induced acoustic tomography[J]. Scientific Reports, 2016, 6: 26118.
[11] TANG S, LAAROUSSI R, CHEN J, et al. 3D breast digital phantom for XACT imaging[J]. Medical Physics, 2016, 43(6): 3389.
[12] HICKLING S, LEGER P, El NAQA I. On the detectability of acoustic waves induced following irradiation by a radiotherapy linear accelerator[J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2016, 63(5): 683-690.
[13] HOELEN C G A, De MUL F F M. A new theoretical approach to photoacoustic signal generation[J]. Journal of the Acoustical Society of America, 1999, 106(2): 695-706.
[14] ANDREEV V G, KARABUTOV A A, SOLOMATIN S V, et al. Optoacoustic tomography of breast cancer with arcarray-transducer[C]// Proceedings of SPIE: The International Society for Optical Engineering.[S. l.]: SPIE, 2000, 3916: 36-47.
[15] HICKLING S, LGER P, El NAGA I. Simulation and experimental detection of radiation-induced acoustic waves from a radiotherapy linear accelerator[C]// IEEE International Ultrasonics Symposium (IUS). Chicago, USA: IEEE, 2014: 29-32.

相似文献/References:

[1]倪东,陈思平,汪天富.基于曲光线跟踪算法的超声成像实时模拟研究[J].深圳大学学报理工版,2012,29(No.4(283-376)):322.[doi:10.3724/SP.J.1249.2012.04322]
 NI Dong,CHEN Si-ping,and WANG Tian-fu.A beam width aware curvilinear ray tracing method for real-time ultrasound simulation[J].Journal of Shenzhen University Science and Engineering,2012,29(3):322.[doi:10.3724/SP.J.1249.2012.04322]
[2]潘晓畅,冯乃章,陈思平.二维Savitzky-Golay数字差分器剪切波弹性成像方法[J].深圳大学学报理工版,2018,35(1):22.[doi:10.3724/SP.J.1249.2018.01022]
 PAN Xiaochang,FENG Naizhang,et al.A shear wave elastography method based on 2D Savitzky-Golay digital differentiator[J].Journal of Shenzhen University Science and Engineering,2018,35(3):22.[doi:10.3724/SP.J.1249.2018.01022]
[3]胡鹏辉,王娜,王毅,等.基于全卷积神经网络的肛提肌裂孔智能识别[J].深圳大学学报理工版,2018,35(3):316.[doi:10.3724/SP.J.1249.2018.03316]
 HU Penghui,WANG Na,WANG Yi,et al.Automatic recognition of levator hiatus based on fully convolutional neural networks[J].Journal of Shenzhen University Science and Engineering,2018,35(3):316.[doi:10.3724/SP.J.1249.2018.03316]
[4]南嘉格列,李锐,王海霞,等.基于深度学习的肝包虫病超声图像分型研究[J].深圳大学学报理工版,2019,36(6):702.[doi:10.3724/SP.J.1249.2019.06702]
 NANJIA Gelie,LI Rui,WANG Haixia,et al.Ultrasound image classification for hepatic echinococcosis using deep learning[J].Journal of Shenzhen University Science and Engineering,2019,36(3):702.[doi:10.3724/SP.J.1249.2019.06702]
[5]蒋超,林静,黄鹏.新型近红外花菁类光声探针用于肼检测[J].深圳大学学报理工版,2020,37(1):33.[doi:10.3724/SP.J.1249.2020.01033]
 JIANG Chao,LIN Jing,and HUANG Peng.Novel near-infrared cyanine-based photoacoustic probe for hydrazine detection[J].Journal of Shenzhen University Science and Engineering,2020,37(3):33.[doi:10.3724/SP.J.1249.2020.01033]

备注/Memo

备注/Memo:
Received:2018-01-25;Accepted:2018-03-16
Foundation:National Natural Science Foundation of China(61271108, 6142780119);Scientific Research Foundation of Guangdong Province (A2017280); Shenzhen Science and Technology Basic Research Foundation (JCYJ20150525092941053)
Corresponding author:Associated professor DIAO Xianfen. E-mail: laodiao@szu.edu.cn
Citation:LIU Gang,CHIN C T,LI Xianming, et al. Simulation and experimental detection of X-ray photo-acoustic[J]. Journal of Shenzhen University Science and Engineering, 2018, 35(3): 324-330.(in Chinese)
基金项目:国家自然科学基金资助项目(61271108,6142780119);广东省医学科研基金资助项目(A2017280);深圳市科技基础研究资助项目(JCYJ20150525092941053)
作者简介:刘刚(1992—),男,深圳大学硕士.研究方向:光声成像.E-mail:2151220111@szu.edu.cn
引文:刘刚,钱建庭,李先明,等.X射线光声成像的信号检测与仿真[J]. 深圳大学学报理工版,2018,35(3):324-330.
更新日期/Last Update: 2018-04-28