[1]曾启明,廖江海,纪震.基于OMAP3530的多参数监护仪设计[J].深圳大学学报理工版,2010,27(2):247-252.
 ZENG Qi-ming,LIAO Jiang-hai,and JI Zhen.Design of multi-parameter monitor with OMAP3530[J].Journal of Shenzhen University Science and Engineering,2010,27(2):247-252.
点击复制

基于OMAP3530的多参数监护仪设计()
分享到:

《深圳大学学报理工版》[ISSN:1000-2618/CN:44-1401/N]

卷:
第27卷
期数:
2010年2期
页码:
247-252
栏目:
生物医学工程
出版日期:
2010-04-30

文章信息/Info

Title:
Design of multi-parameter monitor with OMAP3530
文章编号:
1000-2618(2010)02-0247-06
作者:
曾启明廖江海纪震
深圳大学计算机与软件学院,深圳 518060
Author(s):
ZENG Qi-mingLIAO Jiang-haiand JI Zhen
College of Computer Science and Software Engineering,Shenzhen University,Shenzhen 518060,P.R.China
关键词:
信号处理医疗监护仪OMAP3530双核处理器远程监护小波变换心电检测
Keywords:
signal processingmedical monitorOMAP3530 dual-cote processortele-monitoringwavelet tronsformelectrocardiograph detedion
分类号:
R 318.6;TP 368
文献标志码:
A
摘要:
以美国德州仪器公司最新双核处理器OMAP3530为核心设计了一个新型多参数监护仪,用于监测人体心电、血氧饱和度、无创血压、呼吸及体温等生命体征参数.重点讨论了基于小波变换的心电检测算法,简要介绍其他参数采集模块.样机测试结果表明,该监护仪系统性能稳定,能实时监测和远程传送,正确完成对各项生命体征参数的监测.
Abstract:
A new multi-parameter monitor with Texas Instruments latest dual-core processor OMAP3530 was presented.The monitor is for detecting and processing five life parameters,i.e.,electrocardiograph,oxygen saturation,blood pressure,respiration and body temperature.An algorithm based on wavelet transform for detecting electrocardiograph signal was discussed in detail.The brief introduction of other parameter acquisition modules in the monitor was also included.Experiment results have demonstrated that the performance of the monitor is desirable and the detection accurary of five life parameters satisfies the design requirement.

参考文献/References:

[1]德州仪器公司. 医疗应用设计方案[R].D111103,美国:德州仪器公司,2007.(英文版)
[2]Feild D Q,Feldman C L,Horáek B M.改进的 EASI 导联系统参数:推导、数值、以及性能[J].心电学杂志,2002,35:23-33.(英文版)
[3]余辉,张力新,吕杨生.基于小波变换的QRS波检测[J].生物医学工程与临床,2001,5(2):65-70.
[4]彭玉华.小波变换与工程应用[M].北京:科学出版社, 2005:49-51.
[5]吕文标,马桂玲.多参数监护仪测量原理及应用[J].医疗设备信息,2001(5):21-23.
[6]Hung K.基于WAP技术的远程病人监护系统[J].IEEE生物医学技术汇刊, 2003,7(2):101-107.(英文版)
[7]何庆华,吴宝明,廖维宏,等.振动法血压测量中血压的判定方法[J].生物医学工程学杂志,1998,15(4):369-372.
[8]王义山.多参数监护仪血压参数的检验校准方法探讨[J].中国计量, 2008(2):81.
[9]余波,何为,王平,等.基于嵌入式系统的远程多参数监护系统[J].计算机工程,2008,34(6):252-254.
[10]吴莹,谢家祺,张彩萍.智能多参数监护仪的特点及其临床应用[J].中国组织工程研究与临床应用与临床康复,2009,13(9):1707-1710.



[1]Texas Instruments Incorporated. Information for Medical Applications[R].D111103, USA:Texas Instruments Incorporated, 2007.
[2]Feild D Q,Feldman C L,Horáek B M.Improved EASI coefficients:their derivation,values,and performance[J].Journal of Electrocardiology,2002,35:23-33.
[3]YU Hui,ZHANG Li-xin,LU Yang-sheng.Detection of QRS conplexes based on wavelet transform[J].Biomedical Engineering and Clinical Medicine,2001,5(2):65-70.(in Chinese)
[4]PENG Yu-hua.Wavelet Transform and Technical Application[M].Beijing:Science Press,2005:49-51.(in Chinese)
[5]LU Wen-biao,MA Gui-ling.The measuring principle and application of the multi-parameter monitor[J].Information of Medical Device,2001(5):21-23.(in Chinese)
[6]Hung K.Implementation of a WAP-Based telemedicine system for patient monitoring[J].IEEE Transactions on Information Technology in Biomedicine,2003,7(2):101-107.
[7]HE Qing-hua,WU Bao-ming,LIAO Wei-hong.Determination algorithms in oscillometric blood pressure measurement[J].Journal of Biomedical Engineering,1998,15(4):369-372.(in Chinese)
[8]WANG Yi-shan.The calibration of blood pressure parameter in the multi-parameter monitor[J].China Metrology,2008(2):81.(in Chinese)
[9]YU Bo,HE Wei,WANG Ping,et al.Multipurpose tele-monitoring system based on embedded system[J].Computer Engineering,2008,34(6): 252-254.(in Chinese)
[10]WU Ying,XIE Jia-qi,ZHANG Cai-ping.Features and clinical application of intelligentized multiparameter monitor[J].Journal of Clinical Rehabilitative Tissue Engineering Research, 2009,13(9): 1707-1710.(in Chinese)

相似文献/References:

[1]潘长城,徐晨,李国.解全局优化问题的差分进化策略[J].深圳大学学报理工版,2008,25(2):211.
 PAN Chang-cheng,XU Chen,and LI Guo.Differential evolutionary strategies for global optimization[J].Journal of Shenzhen University Science and Engineering,2008,25(2):211.
[2]李再帏,练松良.改进HHT方法在轨道不平顺信号分析中的应用[J].深圳大学学报理工版,2012,29(No.3(189-282)):270.[doi:10.3724/SP.J.1249.2012.03270]
 LI Zai-wei and LIAN Song-liang.Analysis of track irregularity signal by improved Hilbert-Huang transform[J].Journal of Shenzhen University Science and Engineering,2012,29(2):270.[doi:10.3724/SP.J.1249.2012.03270]

备注/Memo

备注/Memo:
收稿日期:2009-12-11;修回日期:2010-01-28
基金项目:国家自然科学基金资助项目(60872125,60901016);美国德州仪器公司创新基金资助项目
作者简介:曾启明(1984-),男(汉族),广东省清远市人,深圳大学博士研究生.E-mail:venus_tseng@163.com
通讯作者:纪震(1973-),男(汉族),深圳大学教授、博士生导师.E-mail:jizhen@szu.edu.cn
更新日期/Last Update: 2010-05-08