参考文献/References:
[1] Chi Zhang, Dragicevic T, Vasquez J C, et al. Resonance damping techniques for grid-connected voltage source converters with LCL filters: a review[C]// IEEE International Energy Conference. Cavtat, Croatia: IEEE, 2014: 169-176.
[2] 许津铭,谢少军,肖华锋.LCL滤波器有源阻尼控制机制研究[J].中国电机工程学报,2012,32(9):27-33.
Xu Jinming, Xie Shaojun, Xiao Huafeng. Research on control mechanism of active damping for LCL filters[J]. Proceedings of the CSEE, 2012, 32(9): 27-33.(in Chinese)
[3] Bao Chenlei, Ruan Xinbo, Wang Xuehua, et al. Step-by-step controller design for LCL-type grid-connected inverter with capacitor-current-feedback active-damping[J]. IEEE Transactions on Power Electronics, 2014, 29(3): 1239-1253.
[4] Pan Donghua, Ruan Xinbo, Bao Chenlei, et al. Capacitor-current-feedback active damping with reduced computation delay for improving robustness of LCL-type grid-connected inverter[J]. IEEE Transactions on Power Electronics, 2014, 29(7): 3414-3427.
[5] Yang Dongsheng, Ruan Xinbo, Wu Heng. A real-time computation method with dual sampling modes to improve the current control performance of the LCL-type grid-connected inverter[J]. IEEE Transactions on Industrial Electronics, 2015, 62(7): 4563-4572.
[6] Wagner M, Barth T, Alvarez R, et al. Discrete-time active damping of resonance by proportional capacitor current feedback[J]. IEEE Transactions on Industry Applications, 2014, 50(6): 3911-3920.
[7] 邹常跃,刘邦银,段善旭,等.并网逆变器中数字控制延时对系统稳定性的影响及其优化设计[J].中国电机工程学报,2015,35(2):411-417.
Zou Changyue, Liu Bangyin, Duan Shanxu. Influence of delay on system stability and its optimization in grid-connected inverters[J]. Proceedings of the CSEE, 2015, 35(2): 411-417.(in Chinese)
[8] 张兴,陈鹏,余畅舟,等.LCL滤波并网逆变器逆变侧电流多次采样的单闭环控制策略[J].电力系统自动化,2016(11):87-92.
Zhang Xing, Chen Peng, Yu Changzhou, et al. Single closed-loop strategy based on multi-sampled inverter side currents for grid-connected inverters with LCL filters[J]. Automation of Electric Power Systems, 2016(11): 87-92.(in Chinese)
[9] 盘宏斌,欧思程,刘林海,等.LCL型并网逆变器数字单环控制延时影响与稳定域分析设计[J].电力系统自动化,2016,40(6):85-90.
Pan Hongbin, Ou Sicheng, Liu Linhai, et al. Influence on delay and stable domain analysis and design based on digital single-loop control of grid-connected inverter with LCL-filter[J].Automation of Electric Power Systems,2016,40(6): 85-90.(in Chinese)
[10] Wang Jianguo, Yan Jiudun, Zou Jiyan. Inherent damping of single-loop digitally controlled voltage source inverters with LCL filters[J]. IEEE, International Symposium on Industrial Electronics, 2016:487-492.
[11] Zhang Xiaotian, Spencer J W, Guerrero J M. Small-signal modeling of digitally controlled grid-connected inverters with LCL filters[J]. IEEE Transactions on Industrial Electronics, 2013, 60(9): 3752-3765.
[12] Dannehl J, Liserre M, Fuchs F W. Filter-based active damping of voltage source converters with filter[J].IEEE Transactions on Industrial Electronics, 2011, 58(8): 3623-3633.
[13] 许津铭,季林,葛小伟,等.计及逆变器侧电流反馈影响的LCL滤波器参数优化设计[J].中国电机工程学报,2016,36(17):4656-4664.
Xu Jinming, Ji Lin, Ge Xiaowei, et al. LCL-filter optimization design with consideration of inverter-side current feedback control impacts[J]. Proceedings of the CSEE, 2016, 36(17): 4656-4664.(in Chinese)
[14] Wang Jianguo, Yan Jiudun, Jiang Lin, et al. Delay-dependent stability of single-loop controlled grid-connected inverters with LCL filters[J]. IEEE Transactions on Power Electronics, 2015, 31(1): 743-756.
[15] Jalili K, Bernet S. Design of filters of active-front-end two-level voltage-source converters[J]. IEEE Transactions on Industrial Electronics, 2009, 56(5): 1674-1689.
[16] 李泽斌,罗安,田园,等.LCL型光伏并网逆变器电流内环控制方法[J].电网技术,2014,38(10):2772-2778.
Li Zebin, Luo An, Tian Yuan, et al. Inner current loop control method for photovoltaic grid-connected inverter with LCL filter[J].Power System Technology, 2014, 38(10):2772-2778.(in Chinese)
[17] Pan Donghua, Ruan Xinbo, Wang Xuehua, et al. Analysis and design of current control schemes for LCL-type grid-connected inverter based on a general mathematical model[J]. IEEE Transactions on Power Electronics, 2017, 32(6): 4395-4410.
[18] Yepes A G, Vidal A, Malvar J, et al. Tuning method aimed at optimized settling time and overshoot for synchronous proportional-integral current control in electric machines[J]. IEEE Transactions on Power Electronics, 2014, 29(6): 3041-3054.
[19] 阚加荣,谢少军,吴云亚,等.逆变器侧电流反馈的LCL滤波并网逆变器参数设计[J].电力系统自动化,2013,37(17):119-124.
Kan Jiarong, Xie Shaojun, Wu Yunya, et al. Parameter design of LCL filter grid-connected inverter using inverter-side current feedback strategy[J].Automation of Electric Power Systems,2013, 37(17): 119-124.(in Chinese)
[20] Pan Donghua, Ruan Xinbo, Bao Chenlei, et al. Optimized controller design for LCL-type grid-connected inverter to achieve high robustness against grid-impedance variation[J]. IEEE Transactions on Industrial Electronics, 2015, 62(3): 1537-1547.
[21] Liserre M, Teodorescu R, Blaabjerg F. Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values[J]. IEEE Transactions on Power Electronics, 2006, 21(1): 263-272.